### Magnetic Circuits, Hopkinson's Law & MMF Metrology Magnetomotive Force is the magnetic analogue of electromotive force.

Reviewed by Ahmad Faraz · BSCS
Last updated:
Editorial Guidelines

⚙ Input Values

ℱ
A/Wb
m

📊 Results

Converted Target MMF
628.3185
MMF units
MMF in SI (Ampere-turns = At = A)
500
At
MMF in Gilberts (Gb = 0.4π·At)
628.32
Gilberts (Gb)
MMF in Kiloampere-turns (kAt)
0.5
kAt
Hopkinson's Law Magnetic Flux (Φ = ℱ/ℛ)
0.001
Webers (Wb)
Core Magnetic Field Intensity (H = ℱ/l)
2,500
A/m
✦ Hopkinson's Law & Magnetic Circuit Summary
Magnetic Circuit Profile (Solenoid Relay Actuator): Converted MMF = 628.319 gilberts gb. Standard SI Value: ℱ = 500.00 Ampere-turns (At) ≡ 628.32 Gilberts (Gb). Hopkinson's Law Core Magnetic Flux (ℛ = 500,000 A/Wb): Flux Φ = 1.000 mWb (1.0000e-3 Webers). Core Magnetic Field Intensity (l_core = 0.20 m): H = 2.50 kA/m (31.42 Oersteds). Hopkinson's Law Principle: Magnetomotive force (ℱ = N·I) acts as the magnetic analogue of electrical voltage (EMF), driving magnetic flux (Φ) through core reluctance (ℛ) according to Hopkinson's law (ℱ = Φ·ℛ). 1 Ampere-turn equals exactly 0.4π ≈ 1.2566 Gilberts.
Embed on Your Website

Copy and paste this code into your website.

<iframe src="https://calcusolve.com/calculator/magnetomotive-force?embed=true" width="100%" height="600" frameborder="0" loading="lazy" title="Magnetomotive Force (MMF"></iframe>

📐 Formula

Multipliers to SI Base Unit Ampere-turns (At = A)

💡 Practical Example

✅

An electromechanical engineer designing an industrial contactor wound with 500 turns carrying 1.0 Amp calculates the coil generates 500 Ampere-turns (628.3 Gilberts) of MMF, delivering 1.0 mWb of magnetic flux across a 500,000 A/Wb core reluctance.

📖 About Magnetomotive Force (MMF

Magnetic Circuits, Hopkinson's Law & MMF Metrology

Magnetomotive Force is the magnetic analogue of electromotive force (voltage), driving magnetic flux through a magnetic circuit:

  • **
  • Universal MMF Conversion Formulas (SI & CGS Standards)**:

1 Ampere-turn (At) = 0.4π Gilberts (Gb) ≈ 1.256637 Gb = 10^-3 kAt = 0.10 abAt

1 Gilbert (Gb) = (10) / (4π) At ≈ 0.795775 At = 795.775 mAt

  • **
  • Hopkinson's Magnetic Ohm's Law & Core Intensity Equations**:

Φ = FR (Hopkinson's Law Magnetic Flux in Webers, Wb)

H = Fl_core

R = l_coreμ_r μ_0 A

  • **
  • Standard Magnetic Circuit Benchmarks**:
  • Ferrite SMPS Core: 50.0 At 62.83 Gb High-frequency power transformer
  • Solenoid Relay Actuator: 500.0 At 628.32 Gb Φ = 1.0 mWb
  • EV Traction Motor Stator: 2,500.0 At = 2.50 kAt 3,141.6 Gb
  • Superconducting MRI Coil: 250.0 kAt = 250,000 At 314,159 Gb

How to Use This Calculator

Enter your Magnetomotive Force (MMF / ℱ = N·I) (e.g. 500 in ℱ), From Magnetomotive Force Unit — choose from Ampere-turns (At = A - SI Base Standard), Gilberts (Gb = 1/(0.4π) At ≈ 0.7958 At - CGS Unit), Kiloampere-turns (kAt = 1,000 At - Heavy Machinery), To Magnetomotive Force Unit — choose from Gilberts (Gb), Ampere-turns (At), Kiloampere-turns (kAt), Core Magnetic Reluctance (ℛ in A/Wb) (e.g. 500000 in A/Wb), Mean Magnetic Path Length (l_core in meters) (e.g. 0.20 in m), and Magnetic Circuit & Actuator Benchmark — choose from Custom Magnetomotive Force, Industrial Contactor Solenoid (500.0 At = 500 Turns @ 1A) → 628.32 Gilberts | Flux Φ = 1.00 mWb | H = 2,500 A/m, Ferrite Flyback Transformer (50.0 At = 50 Turns @ 1A) → 62.83 Gilberts | High-frequency power core. Verify your units match the formula standard (SI vs imperial) before entering values.

The Formula

Multipliers to SI Base Unit Ampere-turns (At = A)

Worked Example

An electromechanical engineer designing an industrial contactor wound with 500 turns carrying 1.0 Amp calculates the coil generates 500 Ampere-turns (628.3 Gilberts) of MMF, delivering 1.0 mWb of magnetic flux across a 500,000 A/Wb core reluctance.

Understanding Your Result

Force in Newtons (N): 1 N = 1 kg·m/s². Reference values: 1 kg object at Earth's surface weighs 9.81 N, atmospheric pressure 101,325 Pa (N/m²). Pressure benchmarks: car tire 30–35 psi (207–241 kPa), blood pressure systolic 120 mmHg (16 kPa), deep sea at 3,000m depth ~300 atm (30 MPa). Torque = Force × moment arm length — doubling the wrench length doubles the torque for the same applied force. Always verify whether gauge or absolute pressure is required for the application.

💡 Methodological Standards & Calculation Accuracy

  • All calculations are performed client-side in your browser using verified, standards-compliant mathematical algorithms.
  • Results are provided for educational and informational analysis; verify critical applications with certified domain specialists.
  • Ensure input values are entered in consistent units matching the selector options to guarantee accurate outputs.
  • Periodic recalibration is recommended whenever baseline assumptions, operating parameters, or external conditions change.

Results are for informational and educational purposes only. Always verify critical decisions with a qualified professional.

❓ Frequently Asked Questions

What is the relationship between Ampere-turns (At) and Gilberts (Gb)?

The Gilbert (Gb) is the CGS unit of magnetomotive force, named after William Gilbert. 1 Ampere-turn equals exactly 0.4π Gilberts ≈ 1.256637 Gb. Conversely, 1 Gilbert = 10 / (4π) At ≈ 0.795775 Ampere-turns.

What is Hopkinson's Law in magnetic circuits?

Hopkinson's Law (the magnetic equivalent of Ohm's Law) states that magnetic flux (Φ in Webers) equals Magnetomotive Force (ℱ in Ampere-turns) divided by magnetic reluctance: Φ = ℱ / ℛ. Just as voltage drives current through resistance, MMF drives magnetic flux through reluctance.

How do you calculate MMF from coil turn count and current?

Multiply the number of coil turns (N) by the electric current in Amperes (I): ℱ = N × I. For example, a coil with 500 turns carrying 1.0 Amp produces 500 × 1.0 = 500 Ampere-turns.

How do you calculate magnetic field intensity (H) from MMF?

Divide the MMF by the mean magnetic path length of the core (l_core in meters): H = ℱ / l_core. For 500 At over a 0.20 m path: H = 500 / 0.20 = 2,500 A/m.

What happens to MMF across an air gap in a transformer or motor?

Because air has a very low magnetic permeability compared to ferromagnetic steel (µ_iron ~ 1000 to 5000 µ₀), an air gap possesses high reluctance. Consequently, the vast majority of the total coil MMF (often 80% to 95%) is dropped across the air gap.