### Magnetic Flux Density (B), Tesla, Gauss & Energy Density Metrology Magnetic Flux Density ($B$, also referred to as magnetic induction or magnetic B-field) measures the strength and concentration.

Reviewed by Sheraz Share · BSCS
Last updated:
Editorial Guidelines

⚙ Input Values

B
cm²

📊 Results

Converted Flux Density
15,000
Flux Density Units
Flux Density in SI Tesla (T)
1.5
Tesla (T)
Flux Density in Gauss (G)
15,000
Gauss (G)
Flux Density in Microtesla (µT)
1,500,000
µT
Magnetic Energy Density (u = B²/(2μ₀))
895,247
J/m³
Enclosed Magnetic Flux (Φ = B·A)
0.75
Webers (Wb)
✦ Magnetic Metrology & Energy Density Summary
Magnetic Flux Density Profile (1.5T MRI Scanner Bore): Converted B = 15,000 gauss g. Standard SI Value: B = 1.5000 Tesla (T) ≡ 15.000 kG (1500.00 mT). Stored Magnetic Energy Density: u = 895.25 kJ/m³. Enclosed Flux (Area = 5000.00 cm²): Φ = 750.000 mWb (75,000,000 Maxwells). Physical Principle: 1 Tesla represents 1 Weber per square meter (1 T = 10,000 Gauss). A magnetic flux density of 1 Tesla exerts a perpendicular Lorentz force of 1 Newton per meter on a conductor carrying 1 Ampere of current.
Embed on Your Website

Copy and paste this code into your website.

<iframe src="https://calcusolve.com/converter/magnetic-flux-density?embed=true" width="100%" height="600" frameborder="0" loading="lazy" title="Magnetic Flux Density (B"></iframe>

📐 Formula

Magnetic Field Energy Density: u = B^2 / (2 * mu_0) in J/m^3
Enclosed Magnetic Flux: Phi = B * Area (Webers)

💡 Practical Example

✅

A biomedical engineer converts an MRI fringe field safety boundary of 5.0 Gauss into 0.50 Millitesla (500 µT) to mark the five-gauss line beyond which pacemakers and ferromagnetic tools are prohibited.

📖 About Magnetic Flux Density (B

Magnetic Flux Density (B), Tesla, Gauss & Energy Density Metrology

Magnetic Flux Density (B, also referred to as magnetic induction or magnetic B-field) measures the strength and concentration of magnetic flux per unit area:

  • **
  • Universal Magnetic Flux Density Conversion Formulas (SI & CGS)**:

1 Tesla (T) = 10,000 Gauss (G) = 10 kG = 1,000 mT = 10^6\ μT = 10^9 nT

1 Gauss (G) = 10^-4 Tesla (T) = 0.10 mT = 100\ μT = 1,000 mG = 100,000 nT

1 Microtesla (μT) = 0.010 Gauss = 10 mG = 1,000 nT | 1 Gamma (γ) 1 nT = 10^-5 G

  • **
  • Magnetic Energy Density & Lorentz Force Equations**:

u_m = (B^2) / (2μ_0)

F = q v B θ (Lorentz Force on a Moving Charge in Newtons, N)

Φ = B A θ (Total Enclosed Magnetic Flux in Webers, Wb)

  • **
  • Standard Magnetic Induction Benchmarks**:
  • Earth Geomagnetic Surface Field: 50.0\ μT = 0.50 Gauss = 500 mG Planetary magnetic shielding
  • Ceramic Refrigerator Magnet: 10.0 mT = 100.0 Gauss Consumer ferrite magnet
  • NdFeB N52 Neodymium Magnet: 1.45 Tesla = 14,500 Gauss = 14.5 kG High-energy rare-earth
  • Clinical 1.5T MRI Scanner Bore: 1.50 Tesla = 15,000 Gauss u_m = 895.2 kJ/m^3
  • High-Field Hybrid Magnet: 45.0 Tesla = 450,000 Gauss u_m = 805.7 MJ/m^3

How to Use This Calculator

Enter your Magnetic Flux Density (B / Induction) (e.g. 1.5 in B), From Flux Density Unit — choose from Tesla (T = Wb/m² = N/(A·m) - SI Standard), Gauss (G = 10⁻⁴ T = 100 µT - CGS Unit), Millitesla (mT = 10⁻³ T = 10 Gauss), To Flux Density Unit — choose from Gauss (G), Tesla (T), Millitesla (mT), Surface Probe Area (A in cm²) (e.g. 100.0 in cm²), and Magnetic Induction Benchmark — choose from Custom Flux Density, Earth Geomagnetic Surface Field (50.0 µT = 0.50 Gauss = 500 mG), Ceramic Refrigerator Magnet (10.0 mT = 100.0 Gauss). Results update instantly as you type — adjust any value to compare scenarios.

The Formula

Magnetic Field Energy Density: u = B^2 / (2 * mu_0) in J/m^3

Enclosed Magnetic Flux: Phi = B * Area (Webers)

Worked Example

A biomedical engineer converts an MRI fringe field safety boundary of 5.0 Gauss into 0.50 Millitesla (500 µT) to mark the five-gauss line beyond which pacemakers and ferromagnetic tools are prohibited.

Understanding Your Result

Unit conversions are exact by definition within a given measurement system (e.g., 1 km = exactly 1,000 m). Cross-system conversions (metric to imperial) use defined exchange factors: 1 inch = exactly 2.54 cm; 1 pound = 0.45359237 kg. Round your converted result to match the precision of your original measurement — expressing more decimal places than your input justifies implies false accuracy. For regulatory, legal, or safety-critical applications, verify which measurement system is required by the applicable standard.

💡 Methodological Standards & Calculation Accuracy

  • All calculations are performed client-side in your browser using verified, standards-compliant mathematical algorithms.
  • Results are provided for educational and informational analysis; verify critical applications with certified domain specialists.
  • Ensure input values are entered in consistent units matching the selector options to guarantee accurate outputs.
  • Periodic recalibration is recommended whenever baseline assumptions, operating parameters, or external conditions change.

Results are for informational and educational purposes only. Always verify critical decisions with a qualified professional.

❓ Frequently Asked Questions

What is the exact conversion factor between Tesla (T) and Gauss (G)?

1 Tesla equals exactly 10,000 Gauss. Conversely, 1 Gauss equals 0.0001 Tesla (10⁻⁴ T) or 100 Microtesla (100 µT).

What is the physical definition of 1 Tesla?

One Tesla is defined as the magnetic flux density that exerts a force of 1 Newton on a 1-meter long straight conductor carrying an electric current of 1 Ampere perpendicular to the magnetic field = 1 Wb/m² = 1 kg /).

How is magnetic energy density calculated from flux density B?

The volumetric magnetic energy density in free space is u = B² / (2μ₀), where μ₀ = 4π × 10⁻⁷ H/m. For a 1.5 Tesla MRI magnet, u = (1.5)² / = 895,247 J/m³.

What is the strength of Earth's magnetic field in Tesla and Gauss?

Earth's magnetic field at the surface ranges from approximately 25 to 65 Microtesla (0.25 to 0.65 Gauss or 250 to 650 Milligauss), varying by latitude and local geological structures.

What is the '5-Gauss line' in MRI facilities?

The 5-Gauss (0.5 mT) line is the designated safety perimeter surrounding an MRI scanner room beyond which magnetic fields can interfere with cardiac pacemakers, neurostimulators, and attract loose ferromagnetic objects.