⚙ Valores de Entrada

CFM
inches

📊 Resultados

Minimum Round Duct Diameter
13
inches (round)
Equivalent Rectangular Duct Size
13" Wide x 10" High
Actual Calculated Velocity
886
FPM
ACCA Manual D Duct Sizing Advice
ACCA Manual D recommends maintaining friction loss near 0.10 inches w.g. per 100 ft for optimum blower efficiency.
Insertar en su Sitio

Copia y pega este código en tu sitio web.

<iframe src="https://calcusolve.com/es/calculator/duct-size-calculator?embed=true" width="100%" height="600" frameborder="0" loading="lazy" title="HVAC Duct Size & CFM Airflow Calculator"></iframe>

📐 Fórmula

Required Area (sq ft) = Airflow CFM ÷ Target Velocity FPM
Round Duct Diameter (inches) = √[ (4 × Required Area sq in) ÷ π ]
Rectangular Width (inches) = Ceil[ Required Area sq in ÷ Max Height inches ]

💡 Ejemplo Práctico

✅

800 CFM airflow on a residential main trunk (target 900 FPM) with 10" max height constraint: Required Area = 800 / 900 = 0.889 sq ft (128 sq in). Round Duct Diameter = 13 inches | Rectangular Duct = 13" W × 10" H (886 FPM actual velocity).

📖 Acerca de HVAC Duct Size & CFM Airflow Calculator

HVAC duct sizing determines duct dimensions based on airflow volume (CFM) and velocity limits (FPM) to ensure balanced heating/cooling without excessive noise or static pressure loss.

To use the HVAC Duct Size & CFM Airflow Calculator, enter your Required Airflow Volume, Target Air Velocity, Maximum Available Duct Height. The calculator instantly computes Minimum Round Duct Diameter, Equivalent Rectangular Duct Size and more. Results update in real time as you change any input — no submit button needed.

How to Use This Calculator

Enter your Required Airflow Volume (e.g. 800 in CFM), Target Air Velocity — choose from Residential Branch Duct (600 FPM -- Quiet operation), Residential Main Trunk (900 FPM -- Standard), Commercial Main Duct (1200 FPM), and Maximum Available Duct Height (e.g. 10 in inches). Results update instantly as you type — adjust any value to compare scenarios.

The Formula

Required Area (sq ft) = Airflow CFM ÷ Target Velocity FPM

Round Duct Diameter (inches) = √[ (4 × Required Area sq in) ÷ π ]

Rectangular Width (inches) = Ceil[ Required Area sq in ÷ Max Height inches ]

Worked Example

800 CFM airflow on a residential main trunk (target 900 FPM) with 10" max height constraint:

Required Area = 800 / 900 = 0.889 sq ft (128 sq in).

Round Duct Diameter = 13 inches | Rectangular Duct = 13" W × 10" H (886 FPM actual velocity).

Understanding Your Result

Evaluate your result in the context of your specific use case and relevant industry standards or reference values. A single calculated result is a starting point — test two to three scenarios to understand how sensitive the outcome is to your key input assumptions. For high-stakes decisions, verify your result against a secondary source or subject-matter expert before acting.

💡 Rigor Matemático y Contexto de Aplicación

  • Esta herramienta aplica definiciones matemáticas exactas según los estándares internacionales del Sistema Internacional de Unidades (SI).
  • Los errores por redondeo prematuro se propagan en cálculos encadenados; mantenga la máxima precisión en pasos intermedios.
  • Verifique siempre la coherencia dimensional de las variables para asegurar que todas las unidades sean homogéneas y compatibles.
  • Para análisis estadísticos, distinga claramente si el conjunto de datos representa una muestra (n - 1) o la población total (N).
  • Los métodos numéricos implementados en navegador garantizan una precisión de coma flotante de 64 bits (estándar IEEE 754).
  • Compruebe los límites de frontera (valores nulos, infinitos o asintóticos) para validar la robustez del resultado en modelos complejos.
  • Consulte tablas de referencia oficiales y literatura científica para corroborar soluciones en entornos de alta exigencia técnica.
  • Las representaciones gráficas complementarias permiten contrastar visualmente el comportamiento algebraico de las ecuaciones.

Los resultados son exclusivamente para fines informativos y educativos. Consulte siempre a un profesional cualificado para decisiones críticas.

❓ Preguntas Frecuentes

How many CFM does a 12-inch round duct carry?

A 12-inch round duct carries approximately 500 to 700 CFM at standard residential velocities.

What is ACCA Manual D?

ACCA Manual D is the ANSI standard protocol for designing and sizing residential duct systems.

How precise are the results?

Results are calculated to 4 decimal places using standard mathematical formulas. For integer-only problems, results are shown as exact whole numbers.

Can I use this on my phone or tablet?

Yes. The calculator is fully responsive and works on all screen sizes including smartphones, tablets, and desktops.

Explorar Otras Calculadoras